A large amount of materials on the net is devoted to setting up the ZONT EVAN H-1 GSM modem. This article is devoted to setting up an analog with the name ZONT H-1 V, in a modular design for a DIN rail. made in a gray plastic case, top cover with a logo, removable. Connectors are located at the bottom.
The kit includes a modular power supply also for DIN rail mounting. The power cord with plug is missing. At the output - 12 volts direct current. Power is connected to pins 9 and 7, do not confuse polarity!
The protective cover of the modem is removed with a miniature flat screwdriver, under it is a SIM card slot, LEDs and a jumper to turn on the battery. The function of the LEDs is the same as in
The passport indicates the purpose of the contacts in the connector. I will immediately point out that in the passport - an error: normally closed contact - number 3, not 2, as indicated in the passport. We are convinced of this by measuring the resistance between the contacts.
When the yellow LED is on (the boiler is working), contacts 1 and 2 are closed. That is, the 2nd contact is normally open. All gas boilers with a jumper in the thermostatic circuit are connected to contacts 1-2 of the GSM modem (we remove the jumper beforehand).
We connect the temperature sensor in accordance with the diagram in the passport for 4 and 6 pins. Polarity is not confused!
The modem kit also includes a 220/12V converter to bring the 220 Volt alarm signal to an acceptable 12 Volt value. Such a voltage can be safely applied to input "8" of the GSM modem.
The modem settings in the ZONT-ONLINE personal account do not differ from the modem settings.
Additional technical advice can be obtained online, for this, fill out Support request form.
Supply voltage | 10-28V |
Maximum current consumption | 150 mA |
Number of analog inputs | 1 |
Dry contact output (make/break) | 1 |
Type of connected wired temperature sensors | DS 18S20 |
Type of connected radiothermal sensors | , |
Total number of simultaneously connected temperature sensors | 10 |
The maximum allowable length of the cable with temperature sensors | 100 m |
Maximum current through relay contacts | 1000 mA |
Maximum voltage of switched relay contacts | ~ 220 V, = 24 V |
Voice interface | eat |
WEB interface | eat |
1-wire interface | eat |
Operating temperature range | from -30 to +55 °С |
GSM modem frequency bands | 800, 900, 1800, 1900 MHz |
Data link | GPRS |
GSM antenna | external |
Internal non-volatile memory | eat |
Built-in backup battery | 103450-RSV-LD 2000 mAh |
Start-up time | no more than 50 sec |
Average service life | 7 years |
dimensions | 90 x 50 x 55 |
Weight, no more | 0.200 kg |
Housing material | Plastic DIN rail |
WEB interface
Remote control of the boiler
- management of SMS commands;
- control when dialing to the voice menu;
- control via the Internet (WEB-interface and mobile app for Android and iOS devices).
Event Notification
- notification when the measured temperature deviates from the specified threshold values;
- notification of a boiler failure (provided that the thermostat is connected to the emergency exit of the boiler);
- notification of a malfunction of the temperature sensor and the transition of the thermostat to emergency operation;
- notification of loss / restoration of power (mains) (only when the backup battery is on);
Signaling
monitoring the status of additional sensors connected to the "Alarm" input of the thermostat;
Event memory
- a diary of measured temperatures for any period without a statute of limitations;
- date and time of detection of the boiler failure;
- date and time when the boiler and thermostat operation mode was changed;
- executed control commands through the voice menu, sent SMS, software updates;
- date and time of power failure/restoration (mains).
Remote software update
Update current version block firmware without turning it off and dismantling.
Thermostat to control any electric, gas or diesel boiler.
ZONT H-1V Intelligent thermostat for remote control of the heating boiler. When installing a ZONT thermostat, it is possible to simultaneously connect 10 temperature sensors, which allows you to control the temperature in different rooms. For example, the temperature outside, the temperature in the room, in the boiler room, the temperature of the boiler supply, return, boiler, underfloor heating, etc. A time graph is built for each temperature sensor. You can see the change in temperature per day, per week or for any other period of time.
In the event of a power failure, in case of emergency operation of the boiler or the output of the boiler operation parameters beyond a certain range, an SMS notification occurs, phone call or notification to email. The operation of the boiler can be adjusted according to any of the temperature sensors. Comfort, economy and anti-freeze modes can be set. In addition, it is possible to program the desired temperature by time of day throughout the week. Weather-dependent control (PZA) of boiler operation according to temperature curves. In the PZA mode, the thermostat controls the temperature of the coolant based on the outdoor outdoor temperature. When connecting an optional adapter, it is possible remote control boiler according to the OpenTherm protocol, with the transfer of possible error codes and other parameters of the boiler.
The device works through the GPRS channel, using the installed SIM card. The data is sent to a free cloud server. Can be controlled via SMS commands or via voice control, which is undoubtedly convenient for older people who do not use smartphones and tablets. Price tariff plan Reception, a regular SIM card is about 120 rubles per month. For convenience, there is free apps for phone and personal account on the site. You can connect motion sensors, water leakage sensors, gas leakage sensors to the thermostat, with arming and disarming and corresponding notification when triggered. When sensors are triggered or when a boiler alarm signal appears, the device will notify you by telephone numbers specified during setup. All settings are made independently or with the help of an installer, remotely via the Internet and personal account. When the main power is turned off, the device sends information with an alert and switches to work from the built-in battery.
The minimum set of the device includes the thermostat itself with a power supply, one temperature sensor that will be controlled, a SIM card
Modern technologies have firmly entered the lives of many people and made it much more comfortable. Indeed, now we have access to many benefits of civilization, the existence of which was quite difficult to imagine a few years ago. One of the devices that allows you to create a new level of comfort is the system Zont H-1. This system helps to remotely control the temperature in the room, monitor the health of the heating boiler, as well as remotely control it!
Convenient control of the heating system
In the winter season, maintaining a comfortable climate in the house is usually provided by a whole group of heating devices, which are not always convenient to control manually. However, with the smart thermostat Zont H-1 you can easily customize your heating system to suit your needs. Thus, a comfortable temperature will be constantly maintained in the house.
Remote control
In addition, you have the opportunity to control the climate in the house at a distance! You can call or send the necessary command by SMS to enable any mode of operation, find out the balance SIM cards, the current state of the system, etc. This feature will be especially useful for users who may be away on business trips for a long time, leave the city, etc. You can remotely turn on the economical heating mode, and before returning home, create a comfortable heating temperature.
Creating a heating schedule
Zont H-1 allows you to configure the operation of the heating system in accordance with a specific schedule. For example, if you are at home only in the evening and on weekends, the system will maintain a minimum temperature in your absence and provide the necessary heating for your return. Thus, the system allows save energy and your funds.
How does the system work?
The thermostat can be controlled by voice menu, sending SMS-messages or via Internet service via PC or smartphone. To use the Internet service, you do not need to install special programs, any modern web browser(Opera, Chrome, IE 8 and above, Firefox). Access to the service is carried out through the user's personal page on the site zont-online.ru. You can also control the device with special application for Android, which is available for download at Play market.
Through a personal account on the zont-online.ru service. the user needs to set comfortable temperature values, as well as threshold levels for generating alarms when the temperature deviates to a critical value.
Zont H-1 receives information about temperature changes using temperature sensor supplied with the system. Depending on the sensor readings, the thermostat turns off or turns on the output relay that controls the operation of the boiler. This principle of operation allows you to maintain the required temperature in the house.
In the event of a malfunction in the operation of the heating boiler, Zont H-1 will notify the owner, which will allow you to quickly respond to this event.
System functionality
Room temperature alert: t˚above the set threshold t˚below the set threshold Notification when a malfunction occurs: in case of temperature sensor malfunction in case of boiler failure Event memory: temperature sensor readings SMS commands operating mode changes |
Boiler operation mode control: SMS commands via internet service Internet access: permanent connection with the server viewing temperature graphs for any period of time display of the thermostat status (room temperature, current operating mode, emergency operation indication) transfer of accumulated data changing the thermostat operating mode “in one click” entering and editing settings weekly temperature schedule editor Remote software update: Updating the current firmware version comes from personal account user at his command. |
Supply voltage: 10-14 V
Maximum current consumption: 150 mA
One analog input
One dry contact output (make/break)
Maximum current through relay contacts: 1000 mA
WEB interface
1-wire interface
Operating temperature range: from -30 to +55 °С
GSM modem frequency bands: 800, 900, 1800, 1900 MHz
GPRS data channel
Built-in GSM antenna (can be optionally external)
Internal non-volatile memory
Backup battery: BL-5C 1000 mA*N (optional)
Time to enter the operating mode: no more than 50 sec.
Dimensions: 77 x 86 x 33 mm
Weight: 0.200 kg.
Plastic body
Individual packing
External GSM antenna
Terminal block (2 pcs.)
Mounting base
Thermostat
Digital temperature sensor
Network adapter 220/12 V.
The thermostat is not supplied with a battery and a SIM card.
Total weight: 1.19 kg Sold: 29 Made in Russia
Buy GSM thermostat Zont H-1V- means to own a compact thermostat with its own SIM card of any operator, which allows you to control the indoor climate from any phone (satellite, mobile or fixed line), tablet or PC. Most boilers have terminals closed with a jumper (corresponds to the switched on boiler) for connecting a room thermostat. It is to these terminals that the Zont-H-1V modules are connected: this jumper is removed and the Zont H relay contacts are connected in its place.
The Micro Line company releases the Zont H-1V thermostat model, which is almost identical in functionality to the GSM Climate Zont H-1 thermostat, which differs only in different housings and some technical features:
- The relay in H-1V holds 220V, and in H-1 it is designed for 120V;
- Zont H-1V has a 220V->5V adapter for converting a high-voltage boiler alarm signal (available in Vaillant) into a low-voltage signal for Zont input;
- The backup battery in the H-1V module is built-in, while in the H-1 it is not included in the basic configuration and can be purchased separately;
- The firmware of these modules is exactly the same, and the circuits are almost the same.
- Mounted on a DIN rail
Zont H1V will ensure economical consumption of fuel consumed by the boiler for heating, will allow you to remotely set the temperature in the house and monitor the correct operation of the heating boiler, as well as remotely control its operation!
Agree that manual control of heating devices is quite troublesome, and at a distance it is almost impossible. FROM Block Zont H 1V remote control of the heating system is not only possible, but also extremely simple and convenient! No matter how far from home you are, just call or send a command with mobile phone or via the Internet to change the mode of the heating boiler and ensure a comfortable temperature in the house. Convenient, isn't it?
New opportunities!
Additional functions of the device allow not only to save heating costs and control the operation of the heating boiler, but also to monitor the safety of the facility! The user can connect additional sensors such as motion, trip, water leakage, gas leakage, fire and smoke detectors, etc. Information is transmitted through channels mobile communications and the Internet.
Features of the thermostat Zont H-1V
Supports various, preset temperature modes:
Economy - economical fixed temperature.
Comfort - a comfortable fixed temperature (usually a few degrees above the economical one).
Schedule - maintaining the set temperature according to the schedule.
Off - anti-freeze mode
Emergency – thermostat operation mode in case of a faulty temperature sensor.
The module will only call the owner's phone or trusted numbers defined by him, warning him of all changes or emergencies. Accordingly, Zont h-1v can only receive commands from the owner or from "their" phones. Unauthorized access is absolutely excluded - even if someone dialed the number by mistake, the device will ask for a password that only the owner and, for example, other family members or trusted persons know. In addition to SMS-management, the possibility of control through the voice menu is implemented.
In fact, the GSM Zont H-1V module plays the role of your personal assistant - you called him, gave the command, for example, to heat up hotter in advance, and the whole family, as a result, will arrive in a warm and comfortable house. Or vice versa: you forgot to turn down the power in the morning, leaving for work, it’s not a question, you can do it right from work, via the Internet.
Unlike competitors, temperature cannot be controlled from the front panel, and all monitoring and control operations are performed using either personal computer, or mobile devices: smartphone or tablet. This allows the owner to control the situation, wherever he is, while significantly reducing the cost of equipment.
The Zont-H1V unit works even when it fails cellular communication, performing, for example, a predetermined weekly schedule.
It is possible to use control commands in the form of SMS text and even using the voice menu.
Used simple, functional and convenient GUI through a web browser or mobile app. All data is stored on the server and at any time you can view convenient and visual system operation graphs, informational messages or make the necessary settings.
New!
Weather-compensated automatics - energy-efficient heating control taking into account changes in outside temperature (the function is available for modules with firmware version 122:74 and higher)
How does the Zont H1V thermostat control the boiler?
The thermostat measures the temperature in the room and switches the output relay on or off, controlling the operation of the boiler in heating mode so that the temperature inside the room corresponds to the set value.
It controls the temperature in the house and outside, the supply voltage, the technical condition of the boiler and signals in case of an accident or power failure. If the values deviate from the set values, it informs the owner in any pre-selected way: by phone call, SMS message or notification via the Internet.
To use the Internet service, you do not need to install additional software, work is carried out using any modern web browser. Access to the Internet service is carried out through a personal page on the server zont-online.ru
From your personal account on the zont-online.ru Internet service, you must set the desired indoor temperature values, as well as threshold levels for generating alarm messages when the temperature deviates to a critical (emergency) value.
The unit analyzes changes in the temperature inside the room using its own remote temperature sensor. Depending on the measurements made, it turns on or off the output relay that controls the operation of the boiler in heating mode so that the temperature inside the room corresponds to the value of the set operating mode.
In the event of a malfunction of the boiler, the system will immediately notify the owner of this event, which will avoid trouble.
Inputs, outputs and connected equipment
Thermal sensors (wired)
It is connected to 4 and 6 contacts of the thermostat in accordance with the proposed scheme. Up to 10 units can be connected at the same time. The remoteness of the latter in the loop is no more than 100 m. Long branches from the main loop can lead to the inoperability of all sensors.
Boiler control output
Contacts 1, 2 and 3 of the thermostat are intended for connection to a heating boiler. Contact No. 1 is common (O), contact No. 2 is normally closed (NC) and contact No. 3 (NO) is normally open. The device is connected to the boiler contacts intended for connecting a room thermostat.
GSM antenna
It is connected to a separate input and located in the room in such a way as to ensure the most stable reception of the GSM signal.
Main power + 12V
From the mains 220V through the power supply ( network adapter 220/12V) supplied.
Backup power + 3.7V
From the built-in Li-ion accumulator.
Input 1 Analog input - pin #5.
Designed to connect: or security sensors; or signal “Boiler failure”; or room thermostat
Input 2 Digital input - pin #8.
Designed to connect: or security sensors; or signal “Boiler failure”; or room thermostat; or OpenTherm Interface and ML-489 Radio Module.
Important!
It is not possible to simultaneously connect signals from an external room thermostat or “Boiler failure” signals to both inputs.
Can be simultaneously connected to Input 2 OpenTherm Interface and ML-489 Radio Module
Functionality of GSM thermostat Zont H-1V
Remote control of the boiler operation can be carried out:
- SMS commands;
- when dialing to the SIM-card number using the voice menu;
- via the Internet (WEB-interface and mobile applications for Android and for devices based on iOS).
Convenient and simple WEB-interface with the following features:
- displaying the current state of the boiler and the temperature in the room;
- boiler operation control;
- temperature monitoring (inside, outside, coolant) for any selected period of time;
- programming of the boiler according to the schedule;
- Notifications about the operation of additional sensors.
Various event notifications:
- when the measured temperature deviates from the specified threshold values;
- about the boiler failure (provided that the thermostat is connected to the emergency exit of the boiler);
- about the malfunction of the temperature sensor and the transition of the thermostat to emergency operation;
- about the loss or restoration of the power supply, while the presence of a backup battery;
The event log
- a diary of measured temperatures for any period without a statute of limitations;
- date and time of detection of the boiler failure;
- date and time when the boiler and thermostat operation mode was changed;
- list of executed control commands through the voice menu, sent SMS, software updates;
- date and time of loss or restoration of power supply to the mains.
Signaling on the status of additional sensors connected to the "Alarm" input of the thermostat;
Event memory:
- temperature sensor readings;
- date and time of the boiler failure;
- changes in operating modes;
- voice menu commands
- SMS commands;
- software updates (SW);
- power on/off.
Update the current version of the block firmware without turning it off and dismantling it from the user's personal account.
Zont H1V thermostat connection diagrams
Delivery set Zont H-1V
Base unit: 1 pc.
External GSM antenna: 1 pc.
Temperature sensor (digital, wired): 1 pc.
Power supply (network adapter) 220V/12V: 1 pc.
Boiler alarm signal converter 220/5V: 1 pc.
Instruction manual: 1 pc.
Thermostat packaging
Specifications GSM thermostat Zont H-1V
Article: ML13213
Manufacturer: MicroLine (commissioned by Evan)
Supply voltage: 10-28V
Maximum current consumption: 150 mA
Number of inputs: 2
Number of outputs (Type - dry contact, closing / opening): 1
Type of connected wired temperature sensors: DS 18S20
Type of connected radio thermal sensors: ML-703
Total number of simultaneously connected thermal sensors (wired and radio): 10
The maximum allowable length of the loop with temperature sensors: 100 m
Maximum current through relay contacts: 1000 mA
Maximum voltage of switched relay contacts: ~ 220 V, = 24 V
Voice interface: yes
WEB interface: yes
1-Wire interface: yes
Operating temperature range: from -30 to +55 °С
GSM modem frequency bands: 800, 900, 1800, 1900 MHz
Data channel: GPRS
GSM antenna: external
Internal non-volatile memory: yes
Backup power: built-in Li-ion battery 103450-RSV-LD 2000 mAh
Time to reach operating mode: no more than 50 sec
Average service life: 7 years
Overall dimensions, mm: 90 x 50 x 55
Weight, not more than: 0.200 kg
Enclosure: plastic DIN rail
Additional compatible Zont equipment: ML-489, ML-703, Zont Home, OpenTherm interface, Astra-9, Astra 512, Astra C, IO 102-16/2, Astra 361, ML-711, ML-712
Smart thermostat ZONT (ZONT models H-1, H-1V and H-2) is designed to meet the needs of holiday home users. The peculiarity of the situation is when there is no one in the house, but you need to be sure that the heating system is working. Moreover, the inertia of the heating system requires a change in the boiler mode long before the arrival of the owners. All this is solved with the help of our devices and Internet service. ZONT.
Features and principle of operation
Thermostat Feature ZONT-H in that it is focused on the use of the Internet. Now the main trend in this area is cloud service And that's how the thermostat works. Unlike most competitors, it lacks a home control panel. All monitoring and control operations are performed using either a personal computer or mobile devices - a smartphone or tablet. This significantly reduces the cost of equipment, while at the same time allows the user to control the situation, wherever he is.Thermostat ZONT-H works even when the connection is lost, executing a pre-set program, for example, a weekly schedule. Additionally, it is possible to use control commands in the form of SMS text and even using the voice menu.
The user has the ability to use a highly functional and powerful graphical interface through a web browser or mobile application. Convenient and visual graphics, informational messages and settings are available. Data from the product is stored on the server and the user can view the entire history of events and parameters. The user interface has been carefully designed and highly acclaimed by numerous customers.
To meet the needs of different user groups, various models are produced that differ in the type of communication - GSM or WiFi. Structurally, some models are made in a small-sized case of their own design, others - in a standard case on a DIN rail for installation in an electrical cabinet.
The thermostat has 2 inputs for connecting various additional devices.
On the Input 1 can be connected: or ; or with signaled “Boiler failure”; or External room thermostat.
On the Input 2 can be connected: or Security sensors and detectors; or with signaled “Boiler failure”; or External room thermostat; or Interface opentherm And Radio module ML-489.
- Security sensors and detectors , connected to one input must be of the same type according to the connection method. The number of sensors in the loop - ICD, MKD, etc. no more than 10 pieces; detectors of water leakage and gas leakage no more than 5 pcs. The maximum distance of the last in the loop is 100 m.
- FROM signaled “Boiler failure”. For control technical condition boiler and the formation of a notification about its emergency state, the thermostat can be connected to the emergency output of the boiler.
- Room thermostat . When connecting an external room thermostat, it becomes possible to control the boiler both through ZONT-H 1 and through an external room thermostat, the choice of how the control is carried out is done remotely via the Internet service or SMS command "Manual mode".
When operating from an external thermostat, remote monitoring of the room temperature and all notification modes (on an accident, power loss / restoration, alarm events, etc.) will be preserved.
- Radio module ML-489. Thermostat interface module ZONT with radio devices It provides reception and relaying of information from radio devices to the ZONT server
For boilers that have a computerized OpenTherm Interface there is an adapter that allows you to expand the functions of management and control, to ensure fuel economy due to advanced algorithms of the system.
How to choose and operate thermostats correctly
ZONT?
The ZONT H-2 model has a WiFi communication channel and is used where a wireless local area network is already available.
1. Internet traffic is about 60 MB per month*
*indicated with rounding up to 100kb per hour
It is important to take into account that the actual consumption of Internet traffic strongly depends on the nature of the use of the device and the quality of the connection. Accordingly, the worse the communication conditions, the more often the device reconnects to the server, and the more traffic is consumed.
To make the monthly fee easily predictable, we recommend choosing tariffs with unlimited traffic.
Many operators offer tariffs in which the Internet speed drops when a certain limit is reached. Such tariffs are also well suited, because ZONT devices do not have special requirements for connection speed.
If you choose a tariff with a per-megabyte traffic payment, then pay attention to the amount of traffic rounding. At great importance rounding off (for example, more than 100 KB), the operator can count many times more traffic than the device actually consumes. The smaller the rounding size, the better.
2. Calls and SMS
ZONT devices use voice calls and SMS messages only for alarm notification, therefore, choose a tariff based on the expected number of alerts.
Attention! There are tariffs incompatible with work ZONTa
- Since November 2015 on MTS Smart tariffsInternet work blocked in 3G modems . Along with modems, the operator also blocks our devices.
- Option "Tablet XS" from MegaFondesigned only for tablets , and in ZONT devices either does not work at all, or leads to constant loss of communication.
Important!
Flashing is an extremely desirable step when you first turn it on. The fact is that in production the product receives the current firmware, and it is desirable for the user to have the latest one. So we advise you to reflash the thermostat before starting operation.
Flashing should be carried out under the control of the user. Since the communication channel is usually unreliable, you need to make sure that the flashing procedure is successful and the product is back in touch.
Video about ZONT H1V:
youtube video
How to set up a power outage alert
Settings - thermostat setting - input No. 2 - "panic button"
- - polarity of an emergency input - "short circuit on the earth"
- - notifications - alarm events - "your phone" - "envelope"
-save
The difference between ZONT H-1V and ZONT H-1 is as follows:
- the relay in H-1V holds 220V. The relay in H-1 is rated for 120V;
- ZONT H-1V has a 220V->5V adapter for converting a high-voltage boiler alarm signal (available in Vaillant) into a low-voltage one for the Zont input;
- relays have the opposite logic - the information is outdated, it corresponds to products produced before xxx 2015 (see section "connection to the boiler"):
- ZONT H-1 - the boiler heats up when the relay is energized. If the power fails, the relay turns off. The internal battery does not power the relay, so it does not help turn on the relay. Therefore, when planning the system layout, this must be taken into account, for example, power the Umbrella and the boiler from the same UPS;
- ZONT H-1V - the boiler heats up when the relay is de-energized. Therefore, if the power fails, the relay turns off, but the boiler is turned on by the relay contacts. The umbrella can be hung without a UPS, it will know about the power failure and send an SMS about it;
- the battery in the H-1V is built-in, and in the H-1 it is not even included in the basic kit. It can be purchased;
- and most importantly, the firmware of both options are the same. Schemes, almost the same. different cases;
Connection to the boiler WAMOS QX (EVAN)
(For other boilers Evan this scheme does not fit)
The umbrella, wanting to turn on the boiler, closes 1-3, opens 1-2.
The boiler has an input IN. Although it is called an air temperature sensor input, we use it as an input for connecting a thermostat. You can use another, alternative input - a floor heating sensor. They are essentially the same.
Relay ZONT H1 is connected as follows. The central contact of the relay (1) is connected to the IN input. The normally closed relay contact (2) is connected to the "-" input. The normally open relay contact (3) is connected to the "+" input.
To make it clear, the "+" and "-" contacts of the boiler are connected to a 5V power circuit. As a result, the ZONT H1 relay switches them to the IN input.
Test of the first switching on of the boiler, using the example of EVAN WARMOS QX
- Set the set temperature lower than in the room. Make sure that the boiler inlet is ZERO. The boiler should not heat;
- Set the set temperature higher than in the room. Make sure that there is +5V at the boiler inlet. Actually, the boiler must heat the water, and without a multimeter it will be seen that the pipe is heating up hotter and hotter.
Thermal sensor
All sensors are connected in parallel. The web interface has a procedure for assigning a "own name" to each sensor.
Please note that there are many modifications of these sensors on the market and they differ in discreteness. The product comes with a DS18S20 sensor with a resolution of 0.1 degrees. Sometimes users buy sensors on the side. Therefore, we provide additional information on different types sensors:
- DS1820 is an old, discontinued model. Differs in the extended case from all new models. It has a bit depth of 9 bits, which leads to a resolution of 0.5 degrees;
- DS18 S 20 - Has a bit depth of 12 bits, recommended for use. Note that manufacturers label the chip as DS1820, so you can only tell it apart by the case size, it's shorter;
- DS18 B 20 - Has a different work protocol. The ZONT H1 program supports 12 bits for it, that is, a resolution of 0.1 degrees;
If there is already a room thermostat and you want to include ZONT - H in the gap between the boiler and the room thermostat?
Yes, now it is possible. To do this, you need to connect a room thermostat to one of the thermostat inputs.ZONT.
This connection allows you to control the boiler both remotely (via ZONT ) and manually, by commands from this room thermostat. The choice of control method is carried out through the Internet service or SMS command "Manual mode".
When operating from a room thermostat, remote temperature monitoring and all notification modes (on an accident, power loss / restoration, alarm events, etc.) are preserved.
Many are interested in how the digital inputs ZONT H are made?
- Input 2 - may have options:
- Input 1 - may have options:
Relay contacts
Relay diagram:
It can be seen that when the power is turned off, contacts 1 and 2 are closed. This must be taken into account, bearing in mind the situation with the loss of power. The boiler is usually switched off when the control contacts are opened and switched on when they are closed. But, there are also alternatives! Then an external relay is required, which inverts the operation logic. This relay is activated by contacts ZONT H.
Often, ZONT H is connected to the boiler through an Uninterruptible Power Supply (UPS).
First steps to turn on the GSM thermostat ZONT H
- Preparation and setup
- Buy a SIM card (standard size, no micro- or nano-SIM) and top up your balance. Minimum requirement - 5-10 mb and 10 sms (while you play with the settings, just spend it);
- Before using it in the product, it is better if you already have a personal account set up on the website of the telecom operator. It will help you see the dynamics of spending money and traffic and solve emerging problems.
- Set up a suitable place where you record and save accounts and passwords. You will need to do this for your personal account SIM cards, for the ZONT web interface, for the access password from the phone. It's amazing how often we forget passwords :-)
- Before connecting the device to the boiler - set it up "on the table":
- Register yourself on the sitehttps://zont-online.ru/
- Register the device on the same site - there is a sign "add device".
- Install the SIM card (open the receiving clip, fold it up, insert the SIM card into the slots with the cut corner up, soldering the SIM card to the contacts)
- Connect the supplied antenna (there is no internal antenna, so this is a must). Please note that if the room is in the basement or in a poor reception area, then the antenna must be moved as high as possible
- Connect the temperature sensor and power supply (AC adapter).
- < > Dial in the phone text SMS about resetting to factory settings. There are many letters, and the time for sending will be limited, so we advise you to type the text in advance. Do not send SMS yet.
- < The item is optional. Needed if there is no web interface> Dial in the phone text SMS about registration of your phone. There are many letters, and the time for sending will be limited, so we advise you to type the text in advance. FROMserial number write small letters and what's after serial number gotta do space and be sure to write the word " Phone ", and write the number without any hyphens between the numbers. Do not send SMS yet.
- Connect connectors and apply power
- Wait for one of two options for a green signal on the device:
- so that it burns constantly and sometimes goes out for a fraction of a second several times in a row (indicates that there is a network and the signal level is normal). This is an option when there is both a GSM connection and a connection to the server;
- so that it flashes in a series of flashes, at least two flashes, with a pause between flashes.This is an option when the GSM connection is established, but there is no connection to the server. In this case, SMS can be used.
- EIf the green indicator flashes only for a short time once, then there is no GSM connection and it is pointless to send SMS.
- < The item is optional. Required if the SIM card is NOT a MEGAFON or the device was released before September 2015> Send SMS with APN hotspot setting. How to do this is written in the instructions.
- Log in to the web interface and wait for the device to connect. After that, you can add a phone number for voice and SMS notifications in the web interface settings. If this is done, then there is no need to send SMS with the same number. That is, paragraph 14 is not required.
- <The item is optional. Most likely, it will be required in case of repeated passage of the procedure. If the first pass for some reason did not work out>Send SMS for factory reset.After resetting to factory settings, you will need to remove the device from the list and add it again.
- <The item is optional. Required if there is no web interface>Submit SMS about registration of your phone. Wait for the response message "phone number set".
- Before connecting to the boiler
- Try to find out the type of connection (normally closed or normally open), it depends on which contacts on the block to connect the wire from the boiler. To do this, you need to study the documentation for the boiler. You can simulate by connecting a jumper and make sure that the boiler reacts correctly
- Install the device and sensors permanently
- Connection
- Connect the wires from the boiler
- Change modes and monitor the reaction of the boiler
- As soon as the boiler began to adequately respond to the control action, you can start setting up the modes
Backup battery and UPS
The backup battery in the ZONT thermostat is intended only to inform the server and the owner via SMS about the loss of the main 220V power supply. Normally the boiler cannot operate without the main power, so there is no point in controlling the boiler in this situation.
Sometimes the user installs a UPS - source uninterruptible power supply. It is connected to the boiler and it is logical to feed ZONT from it. But, there is a problem, ZONT does not recognize the loss of the main 220V power supply. In this case, you can take "Boiler alarm" for notification. You can buy any cheap power supply or charger with an output voltage of 5V and connect it to this input. The circuit, unfortunately, requires a couple more parts - a resistor (any) and a diode (any):
Set Input 2 in the web interface to ground fault mode.
Some UPSs have a main power failure output. Then you just need to connect it to Input 2 and select one of the "Input Polarity" options - "open" or "short".
It is important to add that SMS and web notification will be not only when an accident occurs, but also when it disappears.
The color of the wires of the temperature sensor supplied
The two strand wire used is misleading to some. It is worth taking a closer look, the one that is "more red" we will call "red". The one that is "blacker" we will call "black". If it's not at all clear, don't be afraid. Turn it on at random and if the sensor works, you will take the readings in the web interface. You can warm one in order to distinguish between several connected in parallel.
How often is data sent to the server?
Sensor readings are sent to the server once a minute. Emerging events (out of tolerance, etc.) - immediately upon occurrence.
Some don't important parameters(information about balance, GSM signal level, etc.) are sent upon request from the server. The server sends requests for this data once every minute or two, but only if the user is online in the web interface or mobile application.
If the web interface does not feel user activity for 10 minutes, then it goes into "sleep mode". In this mode, the web interface stops updating data from the server as you move the mouse. Temperature and event data continues to be sent to the server in real time.
Setting Explanations Input 1
General comment. On the "Status" tab, the "Security" button appears for the options "motion sensor", "delayed motion sensor", "short-to-minus sensor", "minus open sensor". This button can be enabled or disabled, i.e. make the input active or disabled.
For other options, the "Protection" button is absent, that is, it is considered that the input is constantly active.
- "not used" - should be selected if it is not connected. Otherwise, you may receive an alarm
- "delay motion sensor" - triggered when the circuit is opened. At the same time, the delay is 30 seconds. The web interface displays the message "motion detected"
- "motion sensor without delay" - triggered when the circuit is opened. The web interface displays the message "motion detected"
- "water leakage sensor" - analog input is used, operation at voltage less than 2.4V. The web interface displays the message "water leak detected"
- "gas leak sensor" - is triggered when the circuit is interrupted to ground. The web interface displays the message "gas leak".
- "alarm button
- "short circuit sensor"- is triggered by a ground fault
The ZONT H-1V thermostat model has a 220VAC relay, but also a limited current.